Crownway Fuels

SHAREhub · Company management system · v1.0

← All Crownway resources

Dangerous substances and explosive atmospheres procedure

CWF-PRO-DSEAR · Completed fictional example · Owner role: Competent DSEAR and Ex specialist

Fictional arrangement or blank working master. No actual approval, site authorisation or completed evidence is supplied.

Dangerous substances and explosive atmospheres procedure

Crownway Fuels Ltd. CWF-PRO-DSEAR. Version 1.0. Prepared 10 November 2026.

COMPLETED FICTIONAL ARRANGEMENT. This Crownway example supports adaptation and learning. It represents no actual company issue, site approval, signature or completed operational evidence.

Explain who does what, in what sequence, the control rationale, evidence, escalation and safe restart conditions.

Scope and responsibility

BULK; RETAIL. Apply where the site/activity/hazard is present; confirm in the site applicability assessment. Ten English petrol/diesel forecourts and convenience shops, HQ and mobile support. The additional bulk establishment is a separate illustrative scenario. Inventory, regulatory applicability, permissions and site-specific acceptance are unresolved.

Responsible roleRequired action
Competent DSEAR and Ex specialistOwn the arrangement, its current scope and escalation.
Site manager and shift supervisorVerify worksite conditions, coordination, briefing and authorised limits.
Engineering and competent specialistsResolve technical uncertainties, verify protection and retain acceptance evidence.
Workers and contractor performing authorityCheck the agreed method, report change, stop loss of control and provide safe handback.

Information before release

Review current site and equipment information, assessments, permissions, competence, contractor interfaces and emergency readiness. The branch records identify the detailed evidence fields. Missing technical values are resolved from competent site information; do not copy values from teaching models.

Preparation and operation

1 Prepare the activity

Identify dangerous substances, release points, quantities, temperatures, ventilation, people and abnormal conditions. Consider eliminating or reducing the substance and preventing releases before relying on ignition control.

2 Carry out and control the work

A competent specialist evaluates explosive-atmosphere risks, hazardous areas, equipment suitability and interfaces. Establish any required explosion-safety verification before first use and after relevant change, with controlled drawings and technical records.

Control rationale

Vapour, mist and ignition sources must be controlled together; an explosion-zone drawing alone is not a DSEAR assessment.

Stop escalation and return

Stop dispensing, transfer or affected maintenance for an uncontrolled release, failed ventilation, unverified zone/equipment suitability, uncontrolled ignition source or loss of essential protection.

The person controlling the activity makes it safe and informs the site manager. The relevant competent specialist verifies the failed or uncertain safeguard. Operations authorises any restart separately after technical acceptance, applicable permissions, work coordination and a fresh briefing. Record all continuing restrictions.

Verification and follow through

Walk the actual fill, vent, dispenser, drain and work areas against the assessment. Check equipment selection and inspection evidence for the actual zone and substance. Do not derive a hazardous-zone distance from a teaching picture.

Worked decision

A contractor proposes a battery tool beside a fill connection without an assessed work boundary. The site manager suspends the task and obtains competent DSEAR advice, an appropriate method and verified controls before a new work-release decision.

This invented case illustrates a decision and any continuing hold. It is not evidence that Crownway has completed an inspection, test, exposure evaluation or regulatory submission.

Connected documents

ReferenceUse in this branch
CWF-RA-DSEAR-01Site specific DSEAR assessment (Risk assessment)
CWF-PLN-DSEAR-01Hazardous area classification drawings and basis (Plan)
CWF-REG-DSEAR-01Explosion protection measures and verification register (Register)
CWF-CHK-DSEAR-01Hazardous area ignition source control check (Checklist)
CWF-FRM-DSEAR-01DSEAR assessment change and review record (Form)
CWF-CHK-DSEAR-02Dangerous substance storage compatibility check (Checklist)

Retain stable record IDs, actual site or asset, template revision, competent author, date and time, findings, actions, owner, due date and evidence. Set the applicable record-specific retention and access rules before operational use. A review date does not authorise deletion; preserve legal holds.

Guidance and related arrangements

Primary guidance 1

Primary guidance 2

Risk Assessment of Flammable or Explosive Atmospheres

Crownway document overview

Primary guidance checked 10 November 2026 for the described arrangements. Linked legal-register entries keep their own review dates and territorial conditions. Guidance, ACOPs, company controls and direct statutory duties are distinct.

Primary references: dsear | official requirements

Related resources

Primary guidance