Public dispensing and portable petrol containers procedure

CWF-PRO-DISP · Completed fictional example · Owner role: Site manager and shift supervisor

Fictional arrangement or blank working master. No actual approval, site authorisation or completed evidence is supplied.

Public dispensing and portable petrol containers procedure

Crownway Fuels Ltd. CWF-PRO-DISP. Version 1.0. Prepared 10 November 2026.

COMPLETED FICTIONAL ARRANGEMENT. This Crownway example supports adaptation and learning. It represents no actual company issue, site approval, signature or completed operational evidence.

Explain who does what, in what sequence, the control rationale, evidence, escalation and safe restart conditions.

Scope and responsibility

RETAIL. Apply where the site/activity/hazard is present; confirm in the site applicability assessment. Ten English petrol/diesel forecourts and convenience shops, HQ and mobile support. The additional bulk establishment is a separate illustrative scenario. Inventory, regulatory applicability, permissions and site-specific acceptance are unresolved.

Responsible roleRequired action
Site manager and shift supervisorOwn the arrangement, its current scope and escalation. Verify worksite conditions, coordination, briefing and authorised limits.
Engineering and competent specialistsResolve technical uncertainties, verify protection and retain acceptance evidence.
Workers and contractor performing authorityCheck the agreed method, report change, stop loss of control and provide safe handback.

Information before release

Review current site and equipment information, assessments, permissions, competence, contractor interfaces and emergency readiness. The branch records identify the detailed evidence fields. Missing technical values are resolved from competent site information; do not copy values from teaching models.

Preparation and operation

1 Prepare the activity

Assess supervised public dispensing, sightlines, customers needing help, young people, containers, spills, ignition risks and emergency controls. The existing example does not establish unattended trading as an accepted arrangement.

2 Carry out and control the work

Use suitable, serviceable dispensing equipment and clear intervention authority. Apply current petrol-container material, capacity, condition and labelling requirements. Ground-level filling, customer behaviour and ignition prevention require the site method.

Control rationale

Unsafe dispensing, unsuitable containers and collision damage can release fuel while untrained members of the public are present.

Stop escalation and return

Suspend the affected dispenser for spill, leak, impact, uncontrolled ignition source, unsafe customer conduct or inadequate supervision required by the assessed operating model.

The person controlling the activity makes it safe and informs the site manager. The relevant competent specialist verifies the failed or uncertain safeguard. Operations authorises any restart separately after technical acceptance, applicable permissions, work coordination and a fresh briefing. Record all continuing restrictions.

Verification and follow through

Refuse or stop unsafe dispensing safely, communicate the reason and escalate repeated problems. Any proposed unattended or alternative model needs a fresh change and regulatory-interface assessment before use.

Worked decision

A customer presents an unsuitable unlabelled container. The colleague prevents filling and explains the suitability requirement without confrontation. The supervisor records the intervention and checks whether instructions and supervision need improvement.

This invented case illustrates a decision and any continuing hold. It is not evidence that Crownway has completed an inspection, test, exposure evaluation or regulatory submission.

Connected documents

ReferenceUse in this branch
CWF-RA-DISP-01Public dispensing and supervision assessment (Risk assessment)
CWF-CHK-DISP-01Dispenser nozzle hose and emergency stop check (Checklist)
CWF-CHK-DISP-02Portable petrol container and safe dispensing check (Checklist)
CWF-FRM-DISP-01Unsafe dispensing refusal and intervention record (Form)
CWF-PLN-DISP-01Unattended or alternative trading model change assessment (Plan)

Retain stable record IDs, actual site or asset, template revision, competent author, date and time, findings, actions, owner, due date and evidence. Set the applicable record-specific retention and access rules before operational use. A review date does not authorise deletion; preserve legal holds.

Guidance and related arrangements

Primary guidance 1

Primary guidance 2

Sources of Ignition in Workplaces

Crownway document overview

Primary guidance checked 10 November 2026 for the described arrangements. Linked legal-register entries keep their own review dates and territorial conditions. Guidance, ACOPs, company controls and direct statutory duties are distinct.

Primary references: owner petrol station | petroleum

Related resources

Primary guidance